100x Electrical Safety RCD Test Labels BS7671 (1 Roll) 75x50mm 18th Edition

£4.975
FREE Shipping

100x Electrical Safety RCD Test Labels BS7671 (1 Roll) 75x50mm 18th Edition

100x Electrical Safety RCD Test Labels BS7671 (1 Roll) 75x50mm 18th Edition

RRP: £9.95
Price: £4.975
£4.975 FREE Shipping

In stock

We accept the following payment methods

Description

PD IEC/TR 62350:2006 Guidance for the correct use of residual current-operated protective devices (RCDs) for household and similar use.

Connected with this subject is Section 551 Low Voltage Generator Sets. As a PV system is a generating set usually operating in parallel with the normal electrical supply, Regulation 551.7 refers. This applies to the RCD test label, periodic test label, presence of SPD label (new requirement). The only exception is the warning notice of additional supplies which, if required, will still need to be present on the enclosure. RCD testers are designed and manufactured to BS EN 61557-6 Effectiveness of residual current devices (RCD) in TT, TN and IT systems for testing electrical installations. The standard requires that the instrument be able to verify correct disconnection of the supply in the event of a fault but it does not provide requirements for extensive product standard testing. Subsequently, not all instruments will be well suited to carrying out anything more than the most rudimentary of tests. What are the different characteristics of the Type A setting on the test instrument?

Cascaded RCDs for selectivity

Further information on RCD operating and non-operating times can be found in the relevant product standards. Type A and Type AC RCCBs and RCBOs are manufactured to BS EN 61008 and BS EN 61009 respectively, whereas Type F and Type B RCCBs and RCBOs are manufactured to BS EN 62423. There may be some equipment however that would show false readings at this test. It is therefore important that manufacturer’s instructions be consulted and if necessary the equipment disconnected during this 250 V DC test. The testing of RCDs has become more complex with the introduction of various different types of RCD. All RCDs, regardless of type, can detect and respond to an AC waveform. To simplify the testing procedure it is only now a requirement for verification purposes to carry out the AC test that is common to all types. So regardless of RCD type, the effectiveness is deemed to have been verified by testing the device using an AC waveform at a test current of 1 x IΔn. All products in our RCD series are waterproof and weatherproof, and easy to write on with Sharpie pens. Not only that, but they are recyclable and eco-friendly.

Following the release of the 18th Edition Amendment 2 published on 28th March, we have put together a guide to provide everything you need to know on the following areas: Table 4 Maximum values of break time for Type A RCD extracted from BS EN 61008-1:2012+A2:23-1:2012+A11:2015 Some test instruments have a variable trip current setting, if a tripping current of 50 mA at five times I Δn was selected on the Type A setting, a trip current of 350 mA could be simulated (50 x 5 x 1.4 = 350 mA). However, the variable test current feature is not available on all test instruments.Table 51 sets out the specific designation system of colour or alphanumeric code for identification conductors, and is referenced by Regulations 514.4.4, 514.4.6 and 514.5.3. There are effectively three changes to this Table: This is where knowledge of relevant product standards is essential, it would be reasonable to expect a 40 ms maximum disconnection time for a test at five times I Δn as would be the case with an AC test. However, this is not the case as the product standard BS EN 61008 requires a half wave pulsating residual current of 0.35 A (350 mA), see Table 4 extracted from BS EN 61008-1:2012+A2:23-1:2012+A11:2015. It is reasonable, therefore, to use a test current higher than the ‘trip rating’ of an RCD regardless of the application of the RCD.

Different types of RCDs were introduced when the 18th Edition was first published in 2018 with Regulation 531.3. Amendment 2 has gone further saying that Type AC RCDs shall only be used where it is known the load current contains no DC components. This will only be in a purely resistive item of equipment such as a resistive heating element or filament lighting. It is likely then that Type A RCDs as a minimum will generally be used. The Appendix advises on the minimum requirements for text and symbol size, summarized in Table 2 below. In addition, it advises the use of an easy-to-read sans serif font, giving examples of Arial, Calibri, Helvetica and Verdana.

What are the changes to the requirements for RCD testing?

If you think you may have a faulty RCD, firstly ensure there are no factors within the installation that are influencing the results. Always carry out RCD testing in accordance with industry guidance and manufacturer’s instructions. These proposed changes are also reflected in proposed updates to Appendix 7. In addition, the informative Appendix 7 Harmonized cable core colours includes a new item 8: Colour codes for diagrams and specifications, which summarizes (in Table 7F) the BS 7645 colour codes, and recommends that they are used, where required, to identify conductors in operation and maintenance information, such as wiring diagrams and termination schedules. Proposed new Regulation 514.9.2

This is still a consideration for the designer of the installation with Regulation 531.3.2. To achieve this, they should ideally ensure there is no more than 30% of the rated residual operating current due to protective conductor current and/or earth leakage currents (i.e. 9mA for a 30mA device). There is a new indent (ii) to consider the use of RCBOs as opposed to split load arrangements for this purpose. As BS 7671 is now published in digital as well as print format, it is no longer feasible to try to identify the minimum size of text on notices with words such as “not smaller than those illustrated here”. In addition, there are harmonized standards for instructions, technical documentation and safety signs, which apply independently of BS 7671. ii) The use of RCBOs for individual final circuits in residential premises. See also section 314 (Division of Installation). It is also recognized that, for domestic (household) premises, certain instruction notices providing general information can be provided with other documentation, accompanying the Electrical Installation Certificate (EIC), where it is not practicable or desirable to fix the notice in the premise. All mechanical or electrical equipment has a finite lifespan. For RCDs, part of the product standard test procedure is to ensure a minimum number of operating cycles. BS EN 61008 requires RCDs having I Δn > 10 mA are subjected to 2000 operating cycles, each operating cycle consisting of a closing operation followed by an opening operation. This is a combination of manual operation, using the test button and using a test current of I Δn.Higher Risk Residential Buildings are assumed to be residential buildings over 18 m in height or in excess of six storeys, whichever is met first. Should this building incorporate a business premises on the ground floor for example then this too could fall under this requirement. It is essential to understand the limitations of the test instrument and product standard requirements when testing RCDs using the available RCD Type settings on the test instrument.