On modern Honeywell valves, if the powerhead fails it can be removed from the valve body without draining down. However,be warned!With very old Honeywell motorised valves the powerhead could not be removed without draining the water first. If the powerhead was removed from the valve to make it easier to change the motor, it must now be re-attached to the valve. The power head cover can then be refitted and secured with the single screw. Make sure it sits squarely on the powerhead, with no wires pushing out from the sides.

V4043H1056 is a 2 port, 22mm compression, 5-wire, normally-closed zone valve with an auxiliary end switch

Occasionally we come across a Honeywell motorised valve where the powerhead jams but the spindle (actuator shaft) is still free. Where this happens it is usually with the valve jammed open. If all the power to the central heating system is turned off, and the manual lever is still loose across the whole slot, the mechanism may be jammed. The Y Plan and S Plan names are more commonly used when other Honeywell controls are also used (programmer, room thermostat, cylinder thermostat and wiring centre). Where two 2-port motorised valves are fitted (one for the heating circuit and one for the hot water cylinder circuit) the fault may be disguised. Even though one valve only partly opens itself and is unable to fire the boiler, the valve on the other circuit can open fully and fire the boiler. The pump then pushes heated boiler water through both the open valve and the partially open valve. Seized motorised valve spindle in an old Satchwell Sunvic 2-port motorised valve. The water leakage has caused white oxides to form round the brass spindle, making it too stiff to turn The V4043B valves are uncommon and likely to be found in solid fuel systems. These valves fail-safe in the open position in the event of a power failure or valve motor failure.

Synchron valve motors can remain energised and hot for many hours a day, all through the winter. They may eventually fail. A failed Synchron valve motor will prevent a 2-port motorised valve from working. The valve won’t be driven open and the end switch will not be made (connected) so power will not be sent on to the boiler or pump.Honeywell V4073A1039 22mm 3-port mid-position motorised valve showing inlet port AB and outlet ports A and B. This valve can be open to either port A or port B, or to both ports at the same time Whereas the internal electrics of the 2-port valve are quite simple, the internal electrical controls of the V4073A mid-position valve are more complex. Honeywell V4073A1039 22mm 3-port mid-position diverter valve. These are 5-wire valves. When used with other Honeywell controls the setup is know as Y Plan This can be difficult to feel for at first. It is most obvious when the valve has been in the Heating Only position and reverts to the mid-position. The auxiliary circuit (grey and orange wires) is commonly used to operate the boiler and/or the circulating pump. The auxiliary circuit could be set to work at a lower voltage than mains but it is normally carrying mains voltage. It works like this: One of the two wires, typically the grey, is connected to a permanent mains Live supply (about 230V AC in the UK). The other wire, usually the orange, is connected to the Switched Live feed to the boiler.



  • Fruugo ID: 258392218-563234582
  • EAN: 764486781913
  • Sold by: Fruugo

Delivery & Returns

Fruugo

Address: UK
All products: Visit Fruugo Shop