276°
Posted 20 hours ago

Qiumi Zigbee Thermostat Radiator Valve, Smart Programmable Thermostat, Temperature Heater, Alexa,Googlehome Voice Control

£9.9£99Clearance
ZTS2023's avatar
Shared by
ZTS2023
Joined in 2023
82
63

About this deal

As there is no input for external sensors, the TRV always refers to the internal temperature sensor as the reference. Thankfully, these can be calibrated with an offset. A long story short, calibration (and overall position of the thermostat) will be crucial. At the moment I’m not able to confirm if I will need all the Sonoff ZigBee Temperature sensors I deployed to monitor the temperature in each room. If the built-in one is accurate enough I will phase the others out. Below is the default plug-in stored in Flash and automatically loaded. It handles the following: To remove a device from the Zigbee2Tasmota list of devices and from the WebUI, use the command ZbForget or ZbForget . If the device is still connected to the network, it will pop up again later. I.e. ZbForget does not remove a device from the network; else use ZbLeave above. Advanced topic: Device Information ~

Best smart radiator valves tried and tested: From Drayton

for Power On and Power Off ZbBind { "Device" : "Name" , "ToGroup" : 100 , "Endpoint" : 1 , "Cluster" : 6 } ZbBind { "Device" : "Name" , "ToGroup" : 100 , "Endpoint" : 2 , "Cluster" : 6 } # for dimming ZbBind { "Device" : "Name" , "ToGroup" : 100 , "Endpoint" : 1 , "Cluster" : 8 } ZbBind { "Device" : "Name" , "ToGroup" : 100 , "Endpoint" : 2 , "Cluster" : 8 } This command links the device 0xC2EF that will send all commands for cluster 6 (On/off cluster) from endpoint 1 to the target device 0x5ADF on endpoint 1. composed of one or more lines defining the modelId and manufacturerId. If a field is empty, it matches all values cluster>/=/[,mul:][,div:

][,add:] Parameter An attribute synonym can remap an incoming attribute value to another attribute and apply the regular transformation. It can also be used to fix a value and keep the same attribute.ZbSe n d { "device" : "0x3D82" , "send" :{ "Power" : "Off" } } ZbSe n d { "device" : "0x3D82" , "send" :{ "Dimmer" : 128 } } ZbSe n d { "device" : "0x3D82" , "send" :{ "Dimmer" : 254 } } ZbSe n d { "device" : "0x3D82" , "endpoint" : "0x0B" , "send" :{ "Dimmer" : 0 } } Receiving Commands ~ Once all configured, I removed all schedules for each room, leaving only an “Off” schedule late at night. That way HA does not try to compete with the Wiser hub for setting temp in each room. After paring the Danfoss with the Zigbee Bridge, i noticed that i have only a couple of entities in HA. Therefore, i opened a thread here asking for help ( Danfoss Ally eTRV entities). It seems, that the entities that it exposes, are the only ones you need. Secondly they are controlled using node red so work just as they are needed, responding to opened windows or presence at home, sunset times etc. You can dynamically load new files with ZbLoad .zb or unload definitions with ZbUnload .zb. When you reload a file with the same name, it is first unloaded.

TRV) to work with Recommendations for Thermostatic Valves (TRV) to work with

And for Zigbee - Zigbee 3.0 certified Danfoss Ally https://zigbeealliance.org/zigbee_products/danfoss-ally-radiator-thermostat/ MQT : tele /% t opic%/SENSOR = { "ZbReceived" : { "0x8F20" : { "Name" : "Kitchen" , "Voltage" : 2.995 , "Battery" : 98 , "Temperature" : 21.01 , "Humidity" : 53.68 , "Pressure" : 1004.04 , "PressureUnit" : "hPa" , "Endpoint" : 1 , "LinkQuality" : 88 }} Some sections are marked as 'Advanced topic', you can skip them at first and read them only when you need to go deeper.This device supports OTA updates, for more information see OTA updates. # Exposes # Battery (numeric) Position. Value can be found in the published state on the position property. It's not possible to read ( /get) or write ( /set) this value. The unit of this value is %. # Window detection (switch) Either Aeotec Z-Wave Plus TRV https://aeotec.com/z-wave-home-automation/thermostat-radiator-valve-trv/ (which is probably just rebranded Eurotronics with maybe newer firmware). I have overrides to schedules when no-one is home, when the house alarm is put on, further changes are made.

Asda Great Deal

Free UK shipping. 15 day free returns.
Community Updates
*So you can easily identify outgoing links on our site, we've marked them with an "*" symbol. Links on our site are monetised, but this never affects which deals get posted. Find more info in our FAQs and About Us page.
New Comment