Replacement Synchronous Motor for motorised valves ACL Honeywell Landis Gye Satchwell Sopec Tower DIY Replacement 2-Port 3-Port Valve Failure

£9.9£99Clearance
ZTS2023's avatar
Shared by
ZTS2023
Joined in 2023
82
63

About this deal

Drive spindle of a Honeywell motorised valve. It is accessed by removing the valve powerhead. Be warned, with Honeywell motorised valves made pre-1985 you have to drain down first to remove the powerhead! In medium sized or larger properties, using a combi boiler, there may be an additional zone valve external to the boiler which allows the heating to be split into two zones. A normally-closed valve is closed when no power is being applied to it and needs electrical power to drive it open.

If, for example, the heating valve is failing in this way, you will get heat round the radiators while the cylinder hot water is being heated too. When the cylinder is up to temperature, the hot water motorised valve closes and no longer tells the boiler to fire, so the heating now stops too. If the powerhead (actuator) can be safely removed from the valve body (see warning above about pre-1985 Honeywell valves) you can try to turn the spindle. You may need a tool unless you have strong fingers. You must also isolate the electrical supply before removing a Honeywell motorised valve powerhead.Starting with the controls set for Heating Only, hold the lever tight against the right side of the slot. Now get someone to select Hot Water too, so you get Heating and Hot Water together. You may need to turn the cylinder stat up to make it call. As soon as Hot Water is also called, you will hearthe valve start to unwind under the force of the spring, then you will feel the lever “bump” your finger. In normal operation, with a heat-only boiler, central heating water is heated in the boiler and then pumped round the system by a circulating pump. Motorised valves are used to split or divert the flow. The heated water can either be sent to the radiators (or underfloor heating) or to the cylinder coil to heat the domestic hot tap water. The cooled circulating water is then returned to the boiler to be heated again. Much of what we describe also applies to ACL Drayton motorised valves like the Drayton 2-port ZA5/679-2 22mm zone valve and the Drayton 3-port MA1/679 22mm mid-position valve. Iflo motorised valves and British Gas motorised valves have similar faults. It may also apply to the Tower VAL222MV motorised valve, the Siemens CZV222 motorised valve and the Flomasta 27900SX motorised valve. Crimps are metal tubes within plastic insulation, which are flattened using pliers to trap two wires, joining them electrically. These crimps can sometimes be re-opened by using pliers to squeeze together the edges of the flattened tube. This can be done with the plastic in place. If successful it frees the two wires. The plastic insulation may break, in which case the crimp is discarded. Where two 2-port motorised valves are fitted (one for the heating circuit and one for the hot water cylinder circuit) the fault may be disguised. Even though one valve only partly opens itself and is unable to fire the boiler, the valve on the other circuit can open fully and fire the boiler. The pump then pushes heated boiler water through both the open valve and the partially open valve.

The wires to disconnect are the two wires which run from the motor. On earlier motorised valves, these were both joined to other wires using metal crimps encased in plastic. On more recent valves, one wire is joined with a crimp and the other is wired directly to the electrical components of the valve. In larger properties, 28mm valves may be used (the 5-wire 3-port V4073A1088 and the 6-wire 2-port V4043H1106). The 28mm V4043H1106 2-port zone valve has a6 th wire, coloured white. This white wire might not be used. In that case it should be made safe electrically. It will make it easier when re-fitting it (just remember which end the flex was connected or take a picture on your phone). The powerhead can only fit one way round onto the valve body but if space is tight that might not be obvious.Only when both white and grey wires are energised (and the valve goes to the Heating Only position) can the orange wire get its 230V supply via the valve itself. (Remember, the orange wire can also get 230V from the cylinder stat if it is calling and a hot water program is on.)

If it’s the other way round, and the 2-port valve controlling the hot water circuit is failing, it may be less obvious. The heating circuit valve may be open for long periods telling the boiler to fire. If the hot water valve is partially open, you may not run out of hot water. The Honeywell V4073A is a spring-return valve. Port A or port B can be closed by a rubber ball, though never both at the same time. The rubber ball is moved between ports A and B by an actuator shaft or spindle which is driven by the powerhead. The inlet port AB can never be closed; the ball only moves between port A and port B.With the powerhead cover removed you also have access to the screw which retains the motor. The motor can, if necessary, be removed without disconnecting the powerhead from the valve body. Replacement Honeywell SYNCHRON motors are available but are a bit more expensive. For a long time we’ve used the standard SYNCHRON motors as replacements, with very few problems. Sometimes a powerhead is able to drive the valve only part way open but not far enough for the auxiliary circuit end switch to close. This valve will then not be able to tell the boiler to fire. The Honeywell motorised valve faults detailed above are likely to apply to most domestic Honeywell valves. A normally-open valve is open when no power is being applied to it and needs electrical power to drive it closed.

A Switchmaster Midi 3-port valve body with a seized spindle. This motorised valve was also rusting through round the screw in the picture Honeywell powerhead (actuator) jams? When using two 2-port valves, the control system may be known as a Sundial S Plan system or a Honeywell S Plan system. V4043H1106 is a 2 port, 28mm compression, 6-wire, normally-closed zone valve with an auxiliary end switch

Delivery Time

If you know how to work safely with mains voltage electricity, the valve motor can be tested with a multimeter. With the mains electrical supply turned off and isolated, the resistance across the two motor wires (either both blue or both orange) can be tested. To test correctly, at least one of the two motor wires must be disconnected from the heating wiring circuit. If Hot Water is then satisfied (either by the programmer or cylinder stat), the grey wire is energised. As there is still a demand for Heating, the valve will motor to the Heating Only position (port A open; port B closed) and switch a 230V supply onto the orange wire, to power the boiler. Occasionally we come across a Honeywell motorised valve where the powerhead jams but the spindle (actuator shaft) is still free. Where this happens it is usually with the valve jammed open. If all the power to the central heating system is turned off, and the manual lever is still loose across the whole slot, the mechanism may be jammed. System boilers may also have a diverter valve or zone valve built into them and might not have any external zone valves.