Megger TPT420 LCD/LED Two-Pole Voltage Tester

£29.995
FREE Shipping

Megger TPT420 LCD/LED Two-Pole Voltage Tester

Megger TPT420 LCD/LED Two-Pole Voltage Tester

RRP: £59.99
Price: £29.995
£29.995 FREE Shipping

In stock

We accept the following payment methods

Description

The Megger TPT420 Two-Pole Voltage Tester is designed to provide electricians & electrical engineers with a simple, intuitive voltage indicator compatible with both AC and DC voltages. This device can measure AC voltage between 12 to 1000 V and DC voltage between 12 to 1500 V. The TPT420 will even continue to alert the user of a present voltage once the batteries have been completely exhausted. Including a continuity function within 0 to 500 kΩ and a frequency range of 40 to 400Hz, this unit can be applied to numerous situations such as automotive, fire alarm & solar/PV systems.

A bad turn will short and this will be shown by a jump in the ringing frequency of the coil (it becomes in effect a ‘different’ coil at this point in the test). Large frequency jumps can be clearly seen on the tester display, but the instrument’s software also uses mathematical analysis to reveal anomalies that are less easy to spot by eye. On older style CCVTs, the potential terminal is typically accessible. However, for modern CCVTs such as those supplied by Trench, the potential terminal is inaccessible. Even in these cases, however, C2 can still be tested. CCVTs have a potential ground switch that provides the means to ground the potential terminal. With the potential ground switch closed, the carrier terminal can be energised, a low voltage lead connected to the line terminal (top of C1), and a C2 test performed in the GST-guard mode. Note that the carrier terminal must be disconnected and isolated from ground potential and the drain coil (also, if applicable, from any accessory leads) for the C2 test. In addition, the test voltage (typically 500 V) used to energise the carrier terminal must not exceed the voltage rating of the terminal. In summary: To answer these questions, let’s look at an example. When a 415 V motor is assembled, the insulation applied to the wire used to wind the stator has a dielectric strength of approximately 8000 V. During its lifetime, this insulation will degrade primarily due to heat in the motor, but also as a result of environmental conditions and the coil movements which arise from starting, stopping and load changes.

Megger VF5 Voltage Tester Technical Specifications 

These on-line techniques, of course, cannot tell you about all types of incipient faults. Indeed, when warnings are given, a full diagnosis may require complementary off-line testing. In addition, off-line tests are often used on their own in a planned maintenance regime that takes motors off-line for testing and other maintenance activities at appropriate intervals. Compared with on-line tests, off-line tests provide different insights into the motor’s condition; the two approaches to testing are, therefore, complementary. The Megger TPT420 voltage tester is designed to provideelectricians and electrical engineers with an easy-to-use voltage indicating instrument. The meter will continue to warn the operator of dangerous test voltages even when the batteries are exhausted. With both LCD and LED displays, the TPT420provides both AC and DC voltage measurement from 12 to 1000 V AC and up to 1500 V DC. In addition, a continuity function within the range 0 to 500 kΩ, is included and for added safety, continuity, and voltage measurements are also accompanied by an acoustic sounder. Finally, this ergonomic tester is equipped with a bright LED torch, GS38 probe tip shrouds, and an IP64-rated housing. The Megger TPT420 is also supplied with a carry pouch.

In some circumstances, the CVD capacitive reactance can resonate with the magnetizing reactance of the inductive voltage transformer and the compensating reactor cores. This unwanted effect is called ferro-resonance and can give rise to large and damaging voltages across the inductive and capacitive elements. To avoid this, a ferroresonance damping circuit is installed in parallel with one of the secondary windings.

Megger TPT420 LCD/LED Two-Pole Voltage Tester Technical Specifications 

Works below the tipping thresholds of RCDs, RCBOs and safety breakers when testing circuits between phase and earth But what overall voltage is necessary to show up these turn-to-turn faults, and will this voltage be harmful if applied to a fault-free motor? How do the test voltages relate to the dielectric strength of the windings? And it’s the same with a surge test generated by a Baker DX tester. It applies a voltage and rise-time to enable you to see the inter-coil response, but with a signal controlled in voltage, time and energy, so that the impact on the motor is similar to the spikes that the motor receives as a result of typical power-system variations during everyday operation. In fact, it will typically take the pulse 100 ns to travel from one coil-turn to the next, which is equal to the rise time of the pulse. The result is that the pulse produces a significant voltage difference between adjacent turns of the coil, something that it is impossible to achieve with any other test technique. The surge test will, therefore, reveal turn-to-turn insulation weaknesses.

The Megger TPT420 LCD/LED Two-Pole Voltage Tester is an easy-to-use and ergonomic voltage meter optimised for safety and reliability. It is designed for testing electrical installations making it ideal for electricians and electrical engineers. However, it can also be used to test automotive, fire alarm, and solar/ PV systems. Megger TPT420 LCD/LED Two-Pole Voltage Tester Key Features Basic insulation testing, PF tests at 1 Hz, and tip-up testing can be performed with the Megger Delta4000 test set and, with the addition of a DMM, a basic ratio test can be carried out. Ratio validation to an accuracy of ±0.1 % can be carried out with the Delta4000 test set and an accessory. The Megger MRCT test set can also perform basic insulation testing and ratio validation to an accuracy of ±0.1 %, with the added benefit of being able measure the overall burden of the CCVT, thus ensuring that the burden rating has not been exceeded.

A basic ratio test can be carried out by exciting the primary side of the CCVT with a 10 kV source and measuring the secondary voltage with a digital multimeter. However, this supplies no measurement of phase deviation, which is required to validate the accuracy of the CCVT. As mentioned in the previous article, there are many options for testing insulation, and Megger supplies an extensive range of testers for such applications, from 50 V to 15 kV insulation testers, through VLF and AC Tan Delta test sets to diagnostic Dielectric Frequency Response instruments and, under the Baker brand, specialist motor testing equipment up to 40 kV. At its core, a voltage tester is a simple device designed to indicate the presence of electrical voltage in a system or a component. The underlying principle lies in Ohm's Law. This states that the current passing through a conductor between two points is directly proportional to the voltage across the two points.



  • Fruugo ID: 258392218-563234582
  • EAN: 764486781913
  • Sold by: Fruugo

Delivery & Returns

Fruugo

Address: UK
All products: Visit Fruugo Shop